EEZ project – Extension definitions

 

The specific instrument model/type within a larger family of instruments, that is possible to define as Build configurations and described under Settings section, is defined under Extension definitions tab. A newly created project does not contain any instrument definition. Use Add option to create as many different instruments as needed (Fig. 1.).

 

Fig. 1: Add new instrument definition

 

A newly added instrument definition will produce few error caused by automated checking mechanism (Fig. 2). Reported errors pointed to the mandatory fields.

 

Fig. 2: Empty instrument definition errors

The Extension definitions has the following parameters (mandatory parameters are marked bold) that follows the Instrument definition file (IDF) structure of Keysight’s Offline Command Expert command set:

 

Parameter

Explanation

Name

Instrument name, has to be unique.

Description

Instrument specific description that will be displayed together with Build Definition description as specified in Settings section.

Do not build

Exclude instrument from collection that will be made during the IEXT building process.

Build configuration

List of all build configuration defined in Settings section.

Build folder

Destination folder when IEXT will be build. Default value is empty for using the same folder as the project file.

IEXT name

Target IEXT .zip file name, for example rigol_mso1104zs is used to create rigol_mso1104zs_xxx.zip where xxx is defined by IDF revision number.

Image

Instrument picture that will be displayed in ESW for easier instrument recognition. If not specified a default “image no selected” thumbnail will be used. Recommended folder for instrument images is doc/images.

IDN

Identification string that contains manufacturer name, followed by model name that is expected at the beginning of the received result from *IDN? Query (e.g. RIGOL TECHNOLOGIES,DS1054Z).

Properties

Instrument specific ESW properties, if specified will override Properties defined in the Build configurations described in Settings section (e.g. instrument specific color scheme).

IDF name

Instrument name, used also as instrument display name.

IDF short name

Instrument short name, not used by EEZ Studio, but it is stored into IDF file (part of the IEXT .zip package).

IDF firmware version

Instrument firmware version.

IDF GUID

Instrument’s GUID (Globally Unique Identifier). A new value will be generated each time when accompanied “+” option is selected.

IDF revision number (extension version)

Revision number that is used as IEXT .zip file suffix and to distinguish between more IEXT’s revision of the same instrument.

IDF description

Instrument information that will be displayed next to instrument name in ESW IEXT list (e.g. 70 MHz Digital Oscilloscope for Rigol DS1074Z model).

IDF supported models

Supported instrument models, not used by EEZ Studio, but it is stored into IDF file (part of the IEXT .zip package).

IDF revision comments

Additional revision information (e.g. what’s new, etc.).

IDF author

Information about IEXT author (e.g. Envox for EEZ instruments).

SDL friendly name

Instrument friendly name, not used by EEZ Studio, but it is stored into SDL file (part of the IEXT .zip package).

 

Join Waitlist We will notify you when the product is available. Please leave your valid email address below.